A custom integration for Home Assistant that connects to Windhager heating systems via the local InfoWIN webserver (local network only, no cloud access needed) and exposes their data as sensors.
Note: This is an independent community project and is not affiliated with Windhager Zentralheizung GmbH. "Windhager" is a trademark of Windhager Zentralheizung GmbH; it is used here solely to identify the supported devices.
-
Automatically discovers all modules, function groups, and data points/settings of your installation (no manual entry of data points needed)
-
Over 350 sensors per installation, including temperatures, pressures, pump speeds, status and operating values
-
Also exposes around 200 LON network variables (NV's) as additional sensors, e.g. operating hours, pellet consumption, number of ignition cycles – with readable names for the most common ones
-
Write support (experimental – use at your own risk): writable values appear as interactive entities – temperature setpoints (e.g. room temperature setpoint, setback temperature) as number inputs with the correct bounds and step size directly from the device, operating modes (e.g. Betriebswahl: Standby / Heizprogramm 1 / ...) as dropdowns with human-readable labels. Changes are confirmed immediately in the UI without waiting for the next polling cycle.
⚠️ Write support has only been tested on a single installation (BioWIN pellet boiler, firmware S 1.0.2). It uses the same local API endpoint as the official Windhager web interface, with the same ENDUSER credentials – but incorrect values sent to a heating system can cause real problems. Double-check any value you set, and verify the result in the Windhager web interface. Use at your own risk. Feedback on what works (or doesn't) with other installations is very welcome via GitHub Issues. -
Time programs (experimental – use at your own risk): heating circuit and domestic hot water time programs ("Zeitprogramm 1/2/3", "Warmwasser Zeitprogramm", etc.) are exposed as sensors showing their switch points/weekdays as attributes, and can be changed via the
windhager_infowin.set_scheduleservice (seeservices.yamlfor the exact fields, including support for multiple switch-point groups per program, e.g. different values for weekdays vs. Sunday). Detection is fully generic: it reads the device's ownres/xml/StaticNav.xmlresource for the list of available time program positions and their real (translated) names, instead of a hardcoded list – so it should work on any installation, not just this developer's. Only verified on a single installation so far. If it doesn't find any schedules on your installation, please report it via GitHub Issues. -
Time program card (experimental): an optional Lovelace card for comfortably viewing/editing a time program instead of raw sensor attributes/Developer Tools YAML - lives in its own repository for separate HACS (Dashboard/plugin) distribution: windhager-schedule-card.
-
PMX combustion state sensor (BioWIN / PMX controller only): the internal PMX controller state (NV index 27) is translated into readable German labels (Standby, Zündvorbereitung, Zündung, Hochbrennen, Volllast, Modulation, Bereitschaft) instead of raw hex values. Unknown states from other firmware versions fall back to the raw hex value so data collection is never interrupted.
-
"Jetzt aktualisieren" button: trigger an immediate poll of all sensors or NV values without reloading the integration – useful after changing a setpoint or operating mode.
-
NV sensor groups: NV sensors (LON network variables) can be filtered by group based on their standardized LON data type (
snvt_name) — Temperatures, Power & RPM, Counters & Runtimes, Operation & Status, Other. Works across all installations regardless of NV names. Configurable via the Options Flow after first setup. -
Pellet consumption sensor (BioWIN only): dedicated sensor for pellet consumption total (NV index 19) with a configurable unit factor. On a BioWIN 2 Touch, 1 raw unit = 10 kg — set the factor to 10 in the Options Flow to get the result in tonnes.
-
Last known state on startup: all sensors show their last known value immediately after a restart instead of "Unknown" while waiting for the first coordinator refresh (~18s sensors, ~25s NV values).
-
Sensible Home Assistant metadata (units, device classes, state classes for long-term statistics/the Energy dashboard) instead of raw values
-
Multi-language sensor names (German, English, French, Italian – depending on what your Windhager firmware provides), automatically matched to your Home Assistant system language
-
Configurable poll intervals: choose how often the integration polls your heating system (default: 1 minute for sensors, 5 minutes for NV values) via the Options Flow
-
During setup, you can choose which modules (e.g. individual heating circuits) and which sensor groups per module should be created – this selection can be changed at any time afterwards via Settings → Devices & Services → Windhager InfoWIN → Configure
A few things are only configurable after the initial setup completes, via Settings → Devices & Services → Windhager InfoWIN → Configure:
-
NV sensor groups: on initial installation, all NV groups are included by default. To exclude groups you don't need (e.g. system internals under "Betrieb & Status"), open Configure and deselect them in the "NV sensor groups" step.
-
Pellet consumption factor: if your installation is a BioWIN pellet boiler, set the factor to 10 (1 raw unit = 10 kg, result shown in tonnes). The default is 1.0 (raw value, no conversion). You'll find this in the "Sensor calibration" step.
-
The integration catalog (the discovered structure of your heating system) is stored in the integration's data directory and intentionally not deleted when you remove the integration — this means a reinstall skips the ~30s discovery crawl and starts up immediately. If you want a fresh discovery (e.g. after a firmware update), delete the
catalog_*.jsonfile fromcustom_components/windhager_infowin/data/before reinstalling.
- Search for "Windhager InfoWIN" in HACS and install it (or add it as a custom repository if it isn't yet listed in the default HACS store: HACS → Integrations → three-dot menu → Custom repositories → add this repository's URL)
- Restart Home Assistant
- Copy the
custom_components/windhager_infowinfolder into thecustom_componentsdirectory of your Home Assistant installation - Restart Home Assistant
- Settings → Devices & Services → Add Integration
- Search for "Windhager"
- Enter the following:
- Host: IP address or hostname of the Windhager webserver
(e.g.
192.168.1.198). Entering with or withouthttp://and with or without a trailing slash all work fine. - Username: Login for the webserver (often
USERby default after a factory reset) - Password: Password for the webserver (often
123by default after a factory reset)
- Host: IP address or hostname of the Windhager webserver
(e.g.
- The integration will then read the structure of your system (discovery) and let you pick which modules and sensor groups to set up – this can take 10–30 seconds depending on the size of your installation. The result is cached locally and won't be re-fetched on subsequent starts.
If you've previously set up the Windhager app (myComfort/Windhager Connect) with your system, it may have changed the local webserver's password during that initial pairing process, without ever showing it to you in plain text. In that case, two options to get back in:
- You can still view the current password if you go to Windhager Connect click on your System and manually change the url from https://connect.windhager.com/systems/xxx-xxx-xxx-xxx-xxx/parameters to https://connect.windhager.com/systems/xxx-xxx-xxx-xxx-xxx/settings , on the bottom of the page you should see a Button "change Webserverpassword" in the popup you can view the current password or change it there
- If you have access to the Windhager Connect
web portal (same login as the app), there may be a "Change webserver
password" option under your system's settings that lets you reset
it to the default (
123) directly – this didn't appear to be available on every account/system in informal testing, so YMMV. - Otherwise, a factory reset of the webserver (reset button on the device, usually held for >10 seconds, see your device's manual) restores the default username/password.
Note that the app reconnecting to your system afterwards does not necessarily mean it changed the password again – in practice, the password only seems to get changed during the initial pairing, not on every reconnect. So app and local API access aren't necessarily mutually exclusive in the long run, though this hasn't been tested thoroughly across different firmware versions.
This integration was developed and tested against a Windhager installation (BioWIN pellet boiler, built around 2012, multiple heating circuit modules) with an InfoWIN Touch webserver, hardware model RC7030, firmware "S 1.0.2" (2017), MES INFINITY control system.
- A Windhager heating system with MES INFINITY control and a locally reachable InfoWIN / InfoWIN Touch / Webserver Touch (hardware model RC7030), reachable via Digest Auth login
- The fuel type (pellets, wood chips, logs, ...) shouldn't matter – the data structure (OIDs, LON network variables) is independent of the boiler type, as long as the control system is MES INFINITY with an RC7030 webserver.
- Newer devices/firmware versions, where the local web access only shows a "comWinStack API" landing page (see e.g. domfie/windhager-rest-api-documentation). This API appears to have a different structure than the (older) REST API used here – this integration probably won't work with it without significant changes. This has been confirmed by at least one user with a LogWIN2 DELUXE Touch (GitHub Issue #2). If you have such a system and want to try it anyway, I'd appreciate a report via Issue (whether it works or not).
- The older MES PLUS generation (webserver model likely also RC7030, but without the "Touch" display) hasn't been tested independently, but should work given the shared hardware.
- Some users report that firmware updates restrict local API access afterwards, or that the default login differs after a reset. If login doesn't work, a factory reset of the device often helps (reset button held for >10 seconds).
- The "Modulinfo" sensors (Funktionsbezeichnung, Softwareversion Feuerungsautomat, Version HW) show "unknown" on pure heating-circuit modules (HK1/HK2/HK3) – this is not a bug in this integration, it matches exactly what the official Windhager web interface shows for these modules. These fields seem to only be populated on the main module with the actual combustion controller (e.g. BioWIN).
- After a power outage (or any abrupt disconnection), the webserver
has sometimes returned
409 Conflicterrors for a while when polled – the webserver itself still answered normally through its own web interface during this time, so this appears to be a temporary internal state on the device rather than an integration issue. Home Assistant's built-in retry mechanism (ConfigEntryNotReady) will keep retrying automatically (with a backoff capped at 10 minutes, but never giving up entirely) until the webserver recovers on its own, typically without needing to restart Home Assistant or reconfigure the integration. - A single poll takes approximately 17–20 seconds, so poll intervals below 30 seconds are not useful in practice. The NV poll takes approximately 25–30 seconds.
Feedback on success or problems with other installations/firmware versions is very welcome via GitHub Issues.
Bug reports, experiences with other installations/firmware versions, and pull requests are welcome. When reporting an issue, please include:
- Windhager webserver model and firmware version (see the webserver's login page)
- Home Assistant version
- Relevant log output (Settings → System → Logs, filtered by "windhager")