1. Dynamical Model solver example

Let's start with a simple example.

import matplotlib.pyplot as plt
from pathlib import Path
import RFB

path = Path.cwd() / 'Battery.xlsx'
load = RFB.BatteryDataXLSX(path)
battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False)

# Constraints 
battery.DynamicalModel.constraints.update({'SOC_max': 0.99, 'SOC_min': 0.01, 'U_max': 1.7, 'U_min': 0.8})

battery.DynamicalModel.rect_current_args = {'I_high': 3, 'I_low': -3, 't_high': 2600, 't_low': 2600}
dynamics = battery.Solve(t_end=5200, I='rect')

plt.plot(dynamics['I'])
plt.show()

plt.plot(dynamics['U'])
plt.show()
plt.plot(dynamics['C'])
plt.show()

2. Constraints

The following constraints and model behavior is implemented:

  • SOC_max - SOC can't be greater than this value on charge
  • SOC_min - SOC can't be lower than this value on discharge
  • U_max - U can't be greater than this value on charge
  • U_min - U can't be lower than this value on discharge
  • C_max - None of the concentrations can be greater than C_b
  • C_min - None of the concentrations can be lower than 0

! If one of the constraints is voided I is set to 0 i.e. the charge/discharge process is stopped

Constraints have default values:

  • 'SOC_max': 0.99
  • 'SOC_min': 0.01,
  • 'U_max': 100
  • 'U_min': 0
  • 'C_max': [battery.Electrolyte['C_b']] * 8,
  • 'C_min': [0] * 8

Although, recommended values for Vanadium Cells are the following:

  • 'SOC_max': 0.9 (Due to hydrogen reduction 2H+ -> H2 )
  • 'SOC_min': 0.1 (Due to concentration losses)
  • 'U_max': N * 1.65 (Hydrogen reduction)
  • 'U_min': 0.8 * N (Concentration losses)

Where N - number of Vanadium cells

There are several ways to set model constraints: you can pass constraints as a parameter on battery object initialization or use update method for dictionaries. The following code segments are equivalent:

con = {'SOC_max': 0.9, 'SOC_min': 0.1, 'U_max': 1.65, 'U_min': 0.8}
battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], constraints=con, crossover=False)
battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False)
battery.DynamicalModel.constraints.update({'SOC_max': 0.9, 'SOC_min': 0.1, 'U_max': 1.65, 'U_min': 0.8})

3. Dynamical Model

Detailed information on dynamical models can be found in the original repo in the file Dynamical Models.docx >

3.1 Constant current

The following code shows how to solve model for charge/discharge on constant current.

from pathlib import Path
import RFB

path = Path.cwd() / 'Battery.xlsx'
load = RFB.BatteryDataXLSX(path)
battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False)

battery.DynamicalModel.constraints.update({'SOC_max': 0.9, 'SOC_min': 0.1, 'U_max': 1.65, 'U_min': 0.8})

dynamics = battery.Solve(t_end=3000, I=3)
from pathlib import Path
import RFB

path = Path.cwd() / 'Battery.xlsx'
load = RFB.BatteryDataXLSX(path)
battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False)

battery.DynamicalModel.constraints.update({'SOC_max': 0.9, 'SOC_min': 0.1, 'U_max': 1.65, 'U_min': 0.8})

# Just for convenience. You can also set values directly in Battery.xlsx
battery.set_initial_values(battery.C_from_SOC(0.9))

dynamics = battery.Solve(t_end=3000, I=-3)

3.2 Rectangular current pulses

To run solver for rectangular current you shall use on of the following:

battery.Solve(t_end=5200, I='rect')
battery.Solve(t_end=5200, I='rectangular')

There are three ways to set current arguments and the following code snippets are equivalent:

args = {'I_high': 3, 'I_low': -3, 't_high': 2600, 't_low': 2600}
battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False, rect_current=args)
battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False)
battery.DynamicalModel.set_rect_args(3, -3, 2600, 2600)
battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False)
battery.DynamicalModel.rect_current_args = {'I_high': 3, 'I_low': -3, 't_high': 2600, 't_low': 2600}

3.3 Functional currents

You can also use any dependency I(t) in the following way:

from pathlib import Path
import RFB
import math

path = Path.cwd() / 'Battery.xlsx'
load = RFB.BatteryDataXLSX(path)

def I(t):
    return 3 * math.cos(t/1500 * math.pi)

battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False)

battery.DynamicalModel.constraints.update({'SOC_max': 0.9, 'SOC_min': 0.1, 'U_max': 1.65, 'U_min': 0.8})
battery.set_initial_values(battery.C_from_SOC(0.5))

dynamics = battery.Solve(t_end=9000, I=I)

3.4 Crossover and performance degradation.

You can model performance over time with membrane crossover model. Setting crossover flag to true

battery = RFB.VanadiumBattery(load, x=[0.045, 0.4, 2.3*10**(-3)], crossover=False)

On the following image you can see capacity decrease over time. First diagram - concentrations of V2+, V3+ in the tank, second figure- concentrations of V3+ V4+ in the tank, third figure- battery capacity as a function of time.

Note

To speed up the calculation you can set step=100 in battery.Solve()

dynamics= battery.Solve(t_end=100000, step=100)