Skip to content

Latest commit

 

History

History
110 lines (87 loc) · 7.67 KB

README.md

File metadata and controls

110 lines (87 loc) · 7.67 KB

python-ipmi over the Aardvark

Third-party bench tools for driving the IPMC as a Chassis Manager would, kept in a local virtual environment (.venv/, not committed).

Package Version Role
python-ipmi 0.6.1 IPMI library and command-line tool; aardvark IPMB interface; vita (VITA 46.11) subcommands
pyaardvark 0.8.1 Python binding to the Total Phase Aardvark API (bundles the native library for win64, Total Phase EULA in pyaardvark/ext/LICENSE.txt)

Setup

python -m venv tools\python-ipmi\.venv
tools\python-ipmi\.venv\Scripts\python.exe -m pip install python-ipmi pyaardvark

Install the Total Phase USB driver before attaching the adapter. The current bench has the v4.0.0 driver package installed; the API is v6.00. pyaardvark finds the adapter as port 0, serial 2239-477438, firmware 3.51, API 6.00.

How the aardvark interface works

python-ipmi enables the Aardvark as an I2C slave at its own IPMB address (option slave_address, default 0x20, the VITA 46.11 Chassis Manager address), master-writes each request frame to the target, and reads the target's response frame from its slave buffer. One Aardvark is one bus.

Commands

$ipmi = "tools\python-ipmi\.venv\Scripts\ipmitool.exe"
& $ipmi -I aardvark -t 0x82 raw 0x06 0x01          # Get Device ID from the IPMC at 82h
& $ipmi -I aardvark -t 0x82 vita -h                # VITA 46.11 subcommands
& $ipmi -I aardvark -o slave_address=0x10 -t 0x82 raw 0x06 0x01   # Chassis Manager at 10h, as in the captured traffic

-o takes the interface options (port, slave_address, serial_number, enable_i2c_pullups, enable_target_power, enable_fastmode for 400 kHz), as defined by pyipmi/interfaces/aardvark.py. The firmware advertises two IPMB interfaces; this single-Aardvark procedure tests IPMB-A only. The Chassis Manager leaves IPMB-B unused. The sensor-1 example below is read after that initialization.

Keep target power off: the bench wiring carries only SCL, SDA and GND.

Bench checks

Date Check Result
10-23-2026 Address write to 41h (IPMB 82h), pull-ups on, 100 kHz, target power off I2C_STATUS_SLA_NACK: bus free, no IPMC slave yet (expected before Phase 6)

Tier-1 commands from the command line

Every implemented Tier-1 command is reachable from ipmitool.exe. The prefix of every line below is

tools\python-ipmi\.venv\Scripts\ipmitool.exe -I aardvark -t 0x82

(-t 0x82 is the IPMB address of slot 1: 80h + 2 x GA, GA = 1 on the bench build.) The raw form is raw <NetFn> <Cmd> <data bytes...>; the printed answer is the completion code followed by the response data, in hex. A non-zero completion code prints alone (VITA commands add the VSO identifier 03) and ipmitool.exe still exits 0, so a script reads the printed bytes. Each process restarts the IPMB sequence number at 0, so wait more than 3 s between two runs: the IPMC answers a repeated sequence number from its duplicate cache.

tools/board_test_report.py reads this table: the generator runs the Named form and Raw form cells of every row and checks the Expected cell.

# Command (NetFn/Cmd) Named form Raw form Spec Expected on the bench board
C01 Get Device ID (06h/01h) bmc info raw 0x06 0x01 IPMI 2.0 20.1; VITA Table 10.1.1-1 p.172 raw 00 01 80 00 01 02 09 00 00 00 4b 49 00 00 00 00; bmc info shows Device ID 1, Firmware Revision 0.1, IPMI Version 2.0, Product ID 18763 (0x494b), Sensor Device, FRU Inventory Device
C02 Get Self Test Results (06h/04h) none raw 0x06 0x04 IPMI 2.0 20.4; p.172 00 55 00 (55h no error)
C03 Broadcast Get Device ID (06h/01h) none none IPMI 2.0 20.9; p.172 No command-line form: python-ipmi has no broadcast request. The Chassis Manager sends it in its discovery step (tools\chassis-manager\chassis_manager.py, README step 1)
C04 Get Device SDR Info (04h/20h) none raw 0x04 0x20 IPMI 2.0 35.2; p.174 00 0d 01 (13 sensors, static population)
C05 Reserve Device SDR Repository (04h/22h) none raw 0x04 0x22 IPMI 2.0 35.4; p.174 00 xx yy, a non-zero 16-bit reservation ID that changes with every request
C06 Get Device SDR (04h/21h) sdr list, sdr showall raw 0x04 0x21 0x00 0x00 0x0d 0x00 0x00 0xff (record 000Dh, whole record) IPMI 2.0 35.3; p.174 raw 00 ff ff 0d 00 51 12 0f 82 00 01 0b 00 00 00 a0 60 00 c4 49 50 4d 43 (the MC locator record, name IPMC); sdr list and sdr showall list the 7 mandatory Tier-1 sensors, 5 analog rail sensors, die temperature and the IPMC locator (14 records, 13 sensors)
C07 Get Sensor Reading (04h/2Dh) sdr showall (reads every sensor) raw 0x04 0x2d 0x01 (sensor 1, IPMB Link) IPMI 2.0 35.14; VITA Table 10.2.2-1 p.241 00 08 40 02 (single-bus bench state after Chassis Manager initialization)
C08 Get FRU Inventory Area Info (0Ah/10h) none raw 0x0a 0x10 0x00 IPMI 2.0 34.1; p.174 00 00 02 00 (512 bytes, accessed by bytes)
C09 Read FRU Data (0Ah/11h) fru print raw 0x0a 0x11 0x00 0x00 0x00 0x08 (FRU 0, offset 0, 8 bytes) IPMI 2.0 34.2; p.174 raw 00 08 01 00 00 01 12 28 00 c4 (the common header); fru print decodes the board and product areas with the crates/ipmc-defs/src/defs.rs strings (IronKernel, VPX Tier-1 IPMC, IK-T1-000001, IK-IPMC-T1-NUC, ipmc-fru-v1, Tier-1 IPMC Reference, IK-IPMC-T1, 0.1)
C10 Write FRU Data (0Ah/12h) none raw 0x0a 0x12 0x00 0x00 0x00 0x01 0x00 (FRU 0, offset 0, data 01 00: the current first two header bytes) IPMI 2.0 34.3; p.174 00 02 (2 bytes written)
C11 Get VSO Capabilities (2Ch/00h) vita properties raw 0x2c 0x00 0x03 VITA 10.1.3.1 p.182 raw 00 03 00 01 00 22 00 00; vita properties shows Tier 1, Layer 1, 100kHz, 2 IPMB interfaces supported, VITA 46.11, Max FRU Device ID 0x00
C12 Set IPMB State (2Ch/09h) none raw 0x2c 0x09 0x03 0xff 0xff (no change to A or B) VITA 10.1.3.7 p.189 00 03
C13 Get Device Locator Record ID (2Ch/0Dh) none raw 0x2c 0x0d 0x03 0x00 (FRU 0) VITA 10.1.3.11 p.194 00 03 0d 00 (record 000Dh)
C14 Get FRU Address Info (2Ch/40h) vita addrinfo raw 0x2c 0x40 0x03 0x00 (FRU 0) VITA 10.1.3.3 p.186 raw 00 03 41 82 ff 00 01 00; vita addrinfo shows Hardware Address 0x41, IPMB-0 Address 0x82, FRU ID 0x00, Site ID 0x01

Error probes

# Probe Command Answer
E01 Request data too long (Get Device ID with a data byte) raw 0x06 0x01 0x00 c7
E02 VITA request data too long (Get VSO Capabilities with a data byte) raw 0x2c 0x00 0x03 0x00 c7 03
E03 FRU device ID 1 (a subsidiary FRU, Rule 4.2-3) raw 0x0a 0x10 0x01 c9
E04 FRU device ID 1 in Get FRU Address Info raw 0x2c 0x40 0x03 0x01 c9 03
E05 Command not applicable to a Tier-1 IPMC (Cold Reset, Rule 4.2-2) raw 0x06 0x02 c1
E06 Non-zero LUN (LUN 1 on Get Device ID) raw -l 1 0x06 0x01 c2

Write FRU Data persists

raw 0x0a 0x12 <fru id> <offset lo> <offset hi> <data...> writes the FRU image. The IPMC answers 00 <count written> at once and saves the image to its flash log after IPMC_FRU_PERSIST_DELAY_MS (1000 ms) without another write, so the bytes survive a reset. The image is not checksum-checked on write: a write that changes a byte inside the board or product area also has to write that area's checksum byte (the area bytes sum to 0 modulo 256), or fru print and the firmware fru show report a bad checksum. Writes that cross the end of the image return c9; with NVMRO asserted they return 80. Console fru restore puts the built image back. board_test_report.py section F runs this sequence.